HELISEM
®
RANGE
VL SERIES MIXERS
General characteristics
Agitator with direct drive
Lantern with radial bearing
Lower shaft provided with a marine impeller
Rated power from 0,37 to 1,5 kW
Velocity : 1000 tr/m and 1500 tr/m
Capacities
From 0.5 to 5 m
3
approximately
Operating conditions
Atmospheric pressure
Temperature up to 70°C
Main applications
Homogenization
Dissolution
Preparation of reagents
Neutralization
Construction materials
Stainless steel 316L
Painting PU : RAL 1018 on the drive system
(please consult us for any other material)
TYPE VLA
Open tanks from 0,5 to 5 m
3
– Atmospheric pressure – Temperature up to 70°C
Electric characteristics
230/400 V three-phase
50 Hz
IP 55
(please consult us for any other voltage
and frequency)
Options (depending on mixer type)
Special motors (60 Hz)
Halar coating
Second impeller
ATEX mixer
Operational limits
Operation prohibited during draining
Use of variable speed not possible
Not recommended for products sensitive
to shearing
Maximum viscosity of 100mPas
Density < = 1,1